Optimization of The Proportion of Adding Consol SS8 Additive to Concrete Strength
Keywords:
Additive optimization, Compressive strength, Concrete mixture, Consol SS8Abstract
This study investigates the impact of varying proportions of Consol SS8 additive on the compressive strength of concrete. The base concrete mixture comprised cement, water, sand, and gravel, while the additive was added at ratios of 1%, 1.3%, 1.5%, 1.7%, and 2% of cement weight. The compressive strength of the samples was tested after 1, 7, 14, and 28 days of curing. Results indicate that the highest compressive strength was achieved with a 1.5% additive ratio, demonstrating a significant improvement compared to other proportions. Beyond this ratio, the strength exhibited a declining trend, likely due to oversaturation and reduced bonding efficiency. This finding suggests that Consol SS8 can enhance concrete performance when used optimally. Further studies on durability and cost-efficiency are recommended to support practical applications in construction projects.
References
Mulyono, T. (2004). Concrete Technology. Yogyakarta: Andi.
SNI 03-2834-2000. Procedure for Designing Normal Concrete Mixes. National Standardization Agency of Indonesia.
SNI 1974:2011. Method for Testing Concrete Compressive Strength Using Cylindrical Specimens. National Standardization Agency of Indonesia.
Tjokrodimuljo, K. (2007). Concrete Technology. Yogyakarta: Nafiri Offset.